patio heaters, radiant heaters, gas heaters, outdoor heaters, terrace heaters, restaurant heaters, hotel heaters, parasol, infrared heaters, free standing, suspended, propane, alfresco, natural gas, stainless steel, hanging heaters, australian heatersOzGlow Natural Gas OUtdoor Patio Heaters
 
   
  Heater Assembly
   
 
Step 1    
Secure the 3 brackets to the base using the bolts provided These are the longest bolts in the package.  
     
Step 2    
Bolt the pole transition to the top of the legs using the short bolts The frame should now look the same as in the picture at right.  
     
Step 3    
Remove the pipe/hose assembly from the post package. This has been pre assembled and teflon taped. If there is noTeflon tape on the thread of the pipe use an approved thread Sealant. Screw the pipe into the heater head using 2 pipe wrenches.  
     
Step 4    
Fit the pole to the heater head using the screws supplied. Face the warning label to the front.  
     
Step 5    
Fit the reflector to the heater head and secure with the wing nuts and flat washers supplied.  
     
Step 6    
Position the cage over the base and leg assembly and then fit the pole and head assembly.. Feed the flexible hose through into the base assembly. Secure the pole to the base assembly with the M6 nut and bolt supplied.  
     
Step 7    
Using suitable spanners fit the regulator to the hose assembly.  
     
Step 8    
Position your 9 kg gas bottle in the cage, connect the regulator to the bottle and secure the retaining chain. Turn on the gas bottle and using soapy water check all joints for gas leaks.  
   
   
 

Installation, Operation & Maintenance Instructions

The Ozglow P40 patio heater is for use with gas supplied from a 9KG propane bottle. Gas pressure details are on the appliance data plate fitted above the gas valve.

This Ozglow heater is to be installed to the requirements of all local gas authorities.

This Ozglow heater must have the following clearances from combustible materials: 300mm above, 600mm at the sides and 2000mm below. For all other installation requirements refer to code AG 601- gas installations.

Overall height 2370mm, overall width 890mm.

This Ozglow heater is for outdoor installation only. An outdoor area is defined as:

  • With walls on all sides but with no overhead cover
  • Within a partial enclosure that includes an overhead cover and no more than 2 side walls. These side walls may be parallel, or at right angles to each other.
  • Within a partial enclosure that includes an overhead cover and 3 side walls, as long as 30 percent or more of the walls forming the partial enclosure is open and unrestricted.

This Ozglow heater is to be placed on level, stable surfaces.

This Ozglow heater should be inspected before each use. Particular attention should be given to the hose assembly to make sure there is no signs of damage or wear and tear.

This Ozglow heater should be checked at least once a year by a qualified service person.

Keep this Ozglow heater free of cobwebs and in as dust free an area as possible.

If the flame becomes excessively long and yellow or if soot builds up on the emitter mesh turn the heater off and call a qualified service person.

If this ozglow heater will not light or operate normally contact your local authorised service agent or your local gas authority.

When this Ozglow heater has been assembled follow the lighting instructions on the data plate and test the heater operation. On the first light up or when the bottle has been changed it may take several minutes to purge the air from the pilot line.

Some smoke may appear around the emitter screen and reflector for the first minute or two of the initial light up.

To light the pilot

1. Depress the control knob and rotate anti clockwise to the pilot position

2. View the pilot through the pilot hole near the burner

3. Hold the knob in the pilot position until the pilot has been alight for 15 seconds. If the pilot does not light repeat steps 1 - 3

To turn heater on

Rotate the knob anti clockwise from the pilot position to either the high or low positions.

To turn heater off

Rotate the knob clockwise to the pilot position. If you rotate the knob fully clockwise the pilot will also turn off.

   
  Print Back